Petro-chemical Equipment Technology ›› 2025, Vol. 46 ›› Issue (3): 10-13,30.doi: 10.3969/j.issn.1006-8805.2025.03.002
• STATIC EQUIPMENT • Previous Articles
Du Danchao
Received:
Revised:
Accepted:
Online:
Published:
Abstract: External fire is a common accident condition in petrochemical plants and safety valves are usually installed to prevent overpressure of pressure vessels. Reasonable calculation of the discharge capacity of safety valves in fire scenario is an important prerequisite for protecting the safe operation of pressure vessels. This paper provides an overview of the calculation formula for the discharge capacity of safety valves in fire scenario, and discusses the selection and determination methods of key parameters in the formula, aiming to provide reference for engineering designers.
Key words: pressure vessel, safety valve, fire scenario, discharge capacity
Du Danchao. Discussion on Calculation of Safety Valve Discharge Capacity for Pressure Vessels in Fire Scenario in Petrochemical Plants[J].Petro-chemical Equipment Technology, 2025, 46(3): 10-13,30.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://syhgsbjs.sei.com.cn/EN/10.3969/j.issn.1006-8805.2025.03.002
http://syhgsbjs.sei.com.cn/EN/Y2025/V46/I3/10
Discussion on Relief Scheme of Safety Valve of Electric Desalter in CDU/VDU and the Determination of Set Pressure
Optimization of Safety Valve Calculation for Horizontal Vessels with Elliptical Heads under Fire Conditions
Fu Rui
Calculation and Analysis of Liquefied Natural Gas Safety Valves
Discussion on Material Selection for Low-temperature Pressure Vessel
Cited