Petro-chemical Equipment Technology ›› 2025, Vol. 46 ›› Issue (4): 40-45,50.doi: 10.3969/j.issn.1006-8805.2025.04.008

• INSPECTION AND MAINTENANCE TECHNOLOGY • Previous Articles    

Analysis and Repair of Overpressure Deformation of LowGpressure Storage Tank Bottom Plate

Zhang Xu , Li Wenjuan   

  1. SINOPEC Hunan Petrochemical Company Limited, Yueyang, Hunan, 414014
  • Received:2025-03-03 Accepted:2025-06-28 Online:2025-07-15 Published:2025-07-18

Abstract: Aiming at the local deformation of the bottom plate and cracking of the storage tank foundation caused by overpressure in a petrochemical enterprise's lowpressure storage tank, theoretical calculations and finite element failure methods were adopted to conduct reliability analysis of the tank body and foundation, and determine the best repair plan. The study showed that due to the storage tank foundation's ring wall structure with a sandfilled core, the deformation was localized at the bottom plate while the wall plate remained deformationfree. Thus it was judged that the tank was basically reliable, and the focus was on repairing the bottom plate and foundation. Partial replacement of the bottom plate was adopted, and the asphalt sand layer in the middle of the foundation was filled with highpressure grouting. The ring wall foundation was reinforced to evenly distribute the force on the bottom plate. After repair, nondestructive testing was conducted on the bottom plate and the foundation strength was rechecked, both of which met the operational requirements. The storage tank has been operating smoothly for one year without any abnormalities.

Key words: lowpressure storage tank, bottom plate, foundation, failure analysis, deformation