Petro-chemical Equipment Technology ›› 2025, Vol. 46 ›› Issue (5): 51-55.doi: 10.3969/j.issn.1006-8805.2025.05.009
• INSPECTION AND MAINTENANCE TECHNOLOGY • Previous Articles
Song Changqing, Zhang Li
Received:
Revised:
Accepted:
Online:
Published:
Contact:
Abstract: The self-priming centrifugal pumps in petrochemical plants often fail to achieve self-priming during the commissioning phase. This paper analyses the causes of the above-mentioned fault based on the working principle of self-priming centrifugal pumps and actual cases. It identifies various factors that cause self-pri-ming faults and confirms that air leakage from the pump body and excessive pressure drop in the pipeline are the main factors leading to self-priming faults. Aiming at these causes, the paper puts forward suggestions for the equipment layout and pipeline design requirements of self-priming centrifugal pumps. These suggestions and requirements can improve the success rate of commissioning effectively and provide reference for future design work.
Key words: self-priming pumplself-priming centrifugal pumplfault analysislequipment layoutlpipeline design
Song Changqing, Zhang Li. Fault Analysis and Countermeasures for Self-Priming Centrifugal Pump Commissioning in Petrochemical Industry[J].Petro-chemical Equipment Technology, 2025, 46(5): 51-55.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://syhgsbjs.sei.com.cn/EN/10.3969/j.issn.1006-8805.2025.05.009
http://syhgsbjs.sei.com.cn/EN/Y2025/V46/I5/51
Cited