Petro-chemical Equipment Technology ›› 2025, Vol. 46 ›› Issue (5): 51-55.doi: 10.3969/j.issn.1006-8805.2025.05.009

• INSPECTION AND MAINTENANCE TECHNOLOGY • Previous Articles    

Fault Analysis and Countermeasures for Self-Priming Centrifugal Pump Commissioning in Petrochemical Industry

Song Changqing, Zhang Li   

  1. Dalian Branch of China Kunlun Constructing & Engineering Corporation, Dalian, Liaoning, 116085
  • Received:2025-02-17 Revised:2025-09-04 Accepted:2025-08-29 Online:2025-09-15 Published:2025-09-16
  • Contact: Zhang Li E-mail:songchangqing01@cnpc.com.cn

Abstract: The self-priming centrifugal pumps in petrochemical plants often fail to achieve self-priming during the commissioning phase. This paper analyses the causes of the above-mentioned fault based on the working principle of self-priming centrifugal pumps and actual cases. It identifies various factors that cause self-pri-ming faults and confirms that air leakage from the pump body and excessive pressure drop in the pipeline are the main factors leading to self-priming faults. Aiming at these causes, the paper puts forward suggestions for the equipment layout and pipeline design requirements of self-priming centrifugal pumps. These suggestions and requirements can improve the success rate of commissioning effectively and provide reference for future design work.

Key words: self-priming pumplself-priming centrifugal pumplfault analysislequipment layoutlpipeline design