石油化工设备技术 ›› 2023, Vol. 44 ›› Issue (2): 42-47.doi: 10.3969/j.issn.1006-8805.2023.02.009

• 节能环保 • 上一篇    

油气集输管道加热炉的改造和低碳化运行

聂肖虎   

  1. 中国石化销售股份有限公司华中分公司,湖北 武汉 430023
  • 收稿日期:2022-12-30 接受日期:2023-02-28 出版日期:2023-03-15 发布日期:2023-03-17
  • 作者简介:聂肖虎,男,1992年毕业于中国石油大学(华东)化工设备与机械专业,学士,现在中国石化销售华中分公司从事油气储运管理工作,高级工程师。

Transformation and Low-carbon Operation of Heating Furnace for Oil and Gas Gathering and Transportation Pipeline

Nie Xiaohu   

  1. Central China Branch of SINOPEC Sales Co., LTD., Wuhan, Hubei, 430023
  • Received:2022-12-30 Accepted:2023-02-28 Online:2023-03-15 Published:2023-03-17

摘要: 对加热炉进行提标增效改造对油气集输管道的绿色低碳运行具有重要意义。文章以输送三高原油2 949 t/d的魏荆线为例,从油品性质、加热炉工作原理和炉效率等角度详细分析了管道加热炉的改造效果。结果表明:相比于传统直接式加热炉,真空相变加热炉的炉效率提高12%,平均单耗降低0.098 m3/t,每年节约成本37.15万元;每年减少废气排放112万m3,减排二氧化碳当量(CO2e)236 t,实现了低碳减排目标。

关键词: 真空相变加热炉, 油气集输, 热效率, 低碳减排

Abstract: The upgrading and efficiency improvement of heating furnace is significant to the green and low-carbon operation of oil and gas gathering and transportation pipeline. Taking Weijing Line transporting 2,949 t/d of three-high crude oil (refers to crude oil with high wax content, high freezing point and high viscosity) as an example, this paper analyzes the transformation effects of pipeline heating furnace in detail from the aspects of oil properties, heating furnace working principles and furnace efficiency. The results show that compared with the traditional direct heating furnace, the vacuum phase change furnace has an increased efficiency of 12% and the average unit consumption of such furnace is reduced by 0.098 m3/t, which results in annual cost saving of 371,500 yuan. In addition, the annual emission of waste gas is reduced by 1.12 million m3, and the carbon dioxide equivalent (CO2e) emission is reduced by 236 t. The goal of low-carbon emission reduction has been achieved by the transformation of heating furnace.

Key words: vacuum phase change heating furnace, oil and gas gathering and transportation, heat efficiency, low-carbon emission reduction